Skip to main content

What should be in a technical disclosure package for a school district?

A technical disclosure package covers seven things: a data flow diagram, a subprocessor list, hosting region, encryption, retention and deletion, incident response, and AI model disclosure. For a working research prototype, expect 15–30 hours of engineering time to write it. Most of those hours go to finding out what the code actually does with student data.

The seven documents and what each one answers

A district reviewer reads the package to answer one question: what happens to a student’s data from the moment they log in until it is deleted. Each document answers part of that question. If you skip one, the reviewer has to ask you for it, and each back-and-forth can cost a week or more.

Document What it answers Typical length
Data flow diagram Where student data enters, moves, is stored and leaves 1 page plus a legend
Subprocessor list Every third party that touches the data, and why Half a page
Hosting and region Which cloud, which region, who has admin access Half a page
Encryption How data is protected in transit and at rest Half a page
Retention and deletion How long each data type is kept, and how deletion is done and confirmed 1 page
Incident response Who is notified, how fast, and what happens next 1 page
AI model and vendor disclosure Which models see student input, what is sent, and whether the vendor retains it 1 page

Six to eight pages in total is normal. A longer package is not more convincing. The reviewer wants short, specific statements they can check against the district’s data privacy agreement.

A sample outline you can copy

  1. Summary. One paragraph covering what the app does, who uses it (grade band, teachers or students), the study it supports, and the pilot dates.
  2. Data inventory. A table of every field collected: name, type, purpose, whether it identifies a student, and whether it goes into the research dataset.
  3. Data flow diagram. Boxes for the browser, your backend, the database, analytics, the AI provider and the research export. Arrows labeled with the fields that move along them.
  4. Subprocessors. Vendor, service used, data it receives, region, and a link to that vendor’s own data processing terms.
  5. Hosting and access. Cloud provider and region, environments (production versus development), named roles with production access, and whether access requires MFA.
  6. Encryption. TLS version in transit; at-rest encryption for the database, file storage and backups; where keys are managed.
  7. Authentication. How students sign in (district SSO, class codes, teacher-created accounts) and whether students ever enter an email or password.
  8. Retention and deletion. Per-data-type retention periods tied to the study end date, the deletion method, backup expiry, and how you certify deletion to the district.
  9. De-identification for research. How the research export strips or pseudonymizes identifiers, where the key linking IDs is kept, and who can see it.
  10. Incident response. Detection, a named contact, notification timeline to the district, and containment steps.
  11. AI disclosure. Models used, what inputs are sent, retention settings at the provider, content filtering, and whether a human reviews outputs before students see them.
  12. Contacts. The PI, the technical lead, and the institution’s privacy or compliance office.

How to write the parts that usually go wrong

The data flow diagram

Draw it from the running system, not from the proposal. Open the browser’s network tab, run through a full student session, and list every domain the app calls. Font services, error trackers and analytics scripts that a graduate student added for debugging show up here, and each one is a subprocessor the district will want named.

The subprocessor list

Include hosting (AWS, Google Cloud or Firebase), database, email delivery, error monitoring, analytics and any AI provider. If a vendor gets no student data, say so and explain why. Reviewers trust a list that explains its exclusions more than one that leaves them out without comment.

Retention and deletion

Give a date or an event for each data type, such as "identifiable records deleted 90 days after the pilot ends" (only an example; your IRB protocol and data use agreement set the real numbers). Say how backups age out, because deleting the live record while it stays in a 12-month backup is the gap reviewers look for. Describe the deletion certificate you will send.

The AI disclosure

This is the section districts now read most closely. Name the provider and model, state exactly what is sent (student free text, problem context, no names), and state the provider’s retention and training settings for your account. If your study compares prompting strategies or models, list every model in the comparison, not only the default.

FERPA, and COPPA for students under 13, define what the district must protect. Your package describes how the app meets those obligations. The district’s counsel and your institution’s compliance office decide whether it does, so do not write legal conclusions into the document.

What it takes to produce, with numbers

Here is a typical split for a React and Firebase prototype with one AI provider, assuming nobody has documented the system before:

Task Hours
Audit the running app: network calls, stored fields, access roles 4–8
Data inventory and flow diagram 3–5
Subprocessors, hosting, encryption sections 2–4
Retention, deletion and de-identification design 3–6
Incident response and AI disclosure 2–4
Revisions after the first district reply 1–3
Total 15–30

The top of the range is where the audit finds problems that have to be fixed before the document can be true, such as analytics collecting student names or a database open to every lab member. At $85 an hour that comes to roughly $1,300–$2,600. Fixes found during the audit are billed separately.

In one engagement, we took a research prototype to a district-approved classroom pilot in under 30 days: 20 teachers in two districts, with more than 100 framework-compliant problems generated. The disclosure was written alongside the engineering, so the review was not left until after the build.

Mistakes that send a package back

  • Describing the architecture you plan to build rather than the one that is running.
  • Leaving out development tools that still run in production, such as session replay or error trackers that capture form input.
  • Writing "data is encrypted" with no detail on what, where, or who holds the keys.
  • Giving no retention period for backups or for the AI provider’s logs.
  • Treating the research export as out of scope. Districts want to know what leaves their control and in what form.
  • Leaving out a named person with a phone number for incidents.

Frequently asked questions

How long should a technical disclosure package for a school district be?
Six to eight pages is typical, covering seven sections plus a data inventory table. Reviewers prefer short statements they can check against their data privacy agreement. Length on its own does not speed up approval.

Do I need a data flow diagram for a district review?
Yes. It is the document reviewers use to orient themselves before reading the rest. Draw it from the running system, with labeled arrows showing which fields move between the browser, backend, database, AI provider and research export.

What should I disclose about AI models in my research app?
Name each provider and model, what student input is sent, and the provider’s retention and training settings for your account. If the study compares several models or prompting strategies, list all of them. Also say whether outputs are filtered or reviewed before students see them.

Who signs off that the disclosure meets FERPA?
The district’s counsel or privacy office, and your institution’s compliance office, decide whether the app meets FERPA and COPPA obligations. The technical package describes how the system handles data. It should not make legal claims.

Can a graduate student write the disclosure package?
Often, if they built the system and it is simple. The hard part is auditing what the code actually does, which is where undocumented analytics, open database rules and missing backup retention turn up. An outside engineer is worth it when the pilot date is fixed and the audit is likely to find things that need fixing.

Related answers

Preparing for a district review or a pilot?

We offer a free 30-minute review of your pilot plan or draft disclosure. Bring the prototype’s repository or a demo, your pilot timeline, and the district’s or funder’s data requirements. Start a conversation.